Export limit exceeded: 18110 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 10683 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (10683 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-49375 | 2026-04-15 | 9.1 Critical | ||
| Open source machine learning framework. A vulnerability has been identified in Rasa that enables an attacker who has the ability to load a maliciously crafted model remotely into a Rasa instance to achieve Remote Code Execution. The prerequisites for this are: 1. The HTTP API must be enabled on the Rasa instance eg with `--enable-api`. This is not the default configuration. 2. For unauthenticated RCE to be exploitable, the user must not have configured any authentication or other security controls recommended in our documentation. 3. For authenticated RCE, the attacker must posses a valid authentication token or JWT to interact with the Rasa API. This issue has been addressed in rasa version 3.6.21 and all users are advised to upgrade. Users unable to upgrade should ensure that they require authentication and that only trusted users are given access. | ||||
| CVE-2024-49396 | 1 Elvaco | 1 Cme3100 Firmware | 2026-04-15 | N/A |
| The affected product is vulnerable due to insufficiently protected credentials, which may allow an attacker to impersonate Elvaco and send false information. | ||||
| CVE-2024-51398 | 1 Altaitechnologies | 1 Ix500 Firmware | 2026-04-15 | 6.5 Medium |
| Altai Technologies Ltd Altai X500 Indoor 22 802.11ac Wave 2 AP web Management Weak password leakage in the background may lead to unauthorized access, data theft, and network attacks, seriously threatening network security. | ||||
| CVE-2025-34153 | 1 Hyland | 1 Onbase | 2026-04-15 | N/A |
| Hyland OnBase versions prior to 17.0.2.87 (other versions may be affected) are vulnerable to unauthenticated remote code execution via insecure deserialization on the .NET Remoting TCP channel. The service registers a listener on port 6031 with the URI endpoint TimerServer, implemented in Hyland.Core.Timers.dll. This endpoint deserializes untrusted input using the .NET BinaryFormatter, allowing attackers to execute arbitrary code under the context of NT AUTHORITY\SYSTEM. | ||||
| CVE-2025-34139 | 1 Sitecore | 4 Experience Commerce, Experience Manager, Experience Platform and 1 more | 2026-04-15 | N/A |
| A vulnerability exists in Sitecore Experience Manager (XM), Experience Platform (XP), Experience Commerce (XC), and Managed Cloud that could allow an unauthenticated attacker to read arbitrary files. This vulnerability affects all Experience Platform topologies (XM, XP, XC) from 8.0 Initial Release through 10.4 Initial Release and later. This issue affects Content Management (CM) and standalone instances. PaaS and containerized solutions are also affected. | ||||
| CVE-2024-51977 | 2026-04-15 | 5.3 Medium | ||
| An unauthenticated attacker who can access either the HTTP service (TCP port 80), the HTTPS service (TCP port 443), or the IPP service (TCP port 631), can leak several pieces of sensitive information from a vulnerable device. The URI path /etc/mnt_info.csv can be accessed via a GET request and no authentication is required. The returned result is a comma separated value (CSV) table of information. The leaked information includes the device’s model, firmware version, IP address, and serial number. | ||||
| CVE-2025-34110 | 1 Trueconf | 1 Server | 2026-04-15 | N/A |
| A directory traversal vulnerability exists in ColoradoFTP Server ≤ 1.3 Build 8 for Windows, allowing unauthenticated attackers to read or write arbitrary files outside the configured FTP root directory. The flaw is due to insufficient sanitation of user-supplied file paths in the FTP GET and PUT command handlers. Exploitation is possible by submitting traversal sequences during FTP operations, enabling access to system-sensitive files. This issue affects only the Windows version of ColoradoFTP. | ||||
| CVE-2024-51984 | 2026-04-15 | 6.8 Medium | ||
| An authenticated attacker can reconfigure the target device to use an external service (such as LDAP or FTP) controlled by the attacker. If an existing password is present for an external service, the attacker can force the target device to authenticate to an attacker controlled device using the existing credentials for that external service. In the case of an external LDAP or FTP service, this will disclose the plaintext password for that external service to the attacker. | ||||
| CVE-2025-32016 | 2026-04-15 | 4.7 Medium | ||
| Microsoft Identity Web is a library which contains a set of reusable classes used in conjunction with ASP.NET Core for integrating with the Microsoft identity platform (formerly Azure AD v2.0 endpoint) and AAD B2C. This vulnerability affects confidential client applications, including daemons, web apps, and web APIs. Under specific circumstances, sensitive information such as client secrets or certificate details may be exposed in the service logs of these applications. Service logs are intended to be handled securely. Service logs generated at the information level or credential descriptions containing local file paths with passwords, Base64 encoded values, or Client secret. Additionally, logs of services using Base64 encoded certificates or certificate paths with password credential descriptions are also affected if the certificates are invalid or expired, regardless of the log level. Note that these credentials are not usable due to their invalid or expired status. To mitigate this vulnerability, update to Microsoft.Identity.Web 3.8.2 or Microsoft.Identity.Abstractions 9.0.0. | ||||
| CVE-2024-53544 | 2026-04-15 | 9.8 Critical | ||
| NovaCHRON Zeitsysteme GmbH & Co. KG Smart Time Plus v8.x to v8.6 was discovered to contain a SQL injection vulnerability via the getCookieNames method in the smarttimeplus/MySQLConnection endpoint. | ||||
| CVE-2024-53649 | 2026-04-15 | 6.5 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices. | ||||
| CVE-2025-3165 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability classified as critical has been found in thu-pacman chitu 0.1.0. This affects the function torch.load of the file chitu/chitu/backend.py. The manipulation of the argument ckpt_path/quant_ckpt_dir leads to deserialization. An attack has to be approached locally. | ||||
| CVE-2025-31634 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 8.8 High |
| Deserialization of Untrusted Data vulnerability in designthemes Insurance insurance allows Object Injection.This issue affects Insurance: from n/a through <= 3.5. | ||||
| CVE-2024-5726 | 2 Wordpress, Wpdiscover | 2 Wordpress, Timeline Event History | 2026-04-15 | 8.8 High |
| The Timeline Event History plugin for WordPress is vulnerable to PHP Object Injection in all versions up to, and including, 3.1 via deserialization of untrusted input 'timelines-data' parameter. This makes it possible for authenticated attackers, with Contributor-level access and above, to inject a PHP Object. No known POP chain is present in the vulnerable software. If a POP chain is present via an additional plugin or theme installed on the target system, it could allow the attacker to delete arbitrary files, retrieve sensitive data, or execute code. | ||||
| CVE-2024-6880 | 1 Jan Syski | 1 Megabip | 2026-04-15 | N/A |
| During MegaBIP installation process, a user is encouraged to change a default path to administrative portal, as keeping it secret is listed by the author as one of the protection mechanisms. Publicly available source code of "/registered.php" discloses that path, allowing an attacker to attempt further attacks. This issue affects MegaBIP software versions below 5.15 | ||||
| CVE-2024-6960 | 1 Mvnrepository | 1 H2o-core | 2026-04-15 | 7.5 High |
| The H2O machine learning platform uses "Iced" classes as the primary means of moving Java Objects around the cluster. The Iced format supports inclusion of serialized Java objects. When a model is deserialized, any class is allowed to be deserialized (no class whitelist). An attacker can construct a crafted Iced model that uses Java gadgets and leads to arbitrary code execution when imported to the H2O platform. | ||||
| CVE-2025-30371 | 1 Metabase | 1 Metabase | 2026-04-15 | N/A |
| Metabase is a business intelligence and embedded analytics tool. Versions prior to v0.52.16.4, v1.52.16.4, v0.53.8, and v1.53.8 are vulnerable to circumvention of local link access protection in GeoJson endpoint. Self hosted Metabase instances that are using the GeoJson feature could be potentially impacted if their Metabase is colocated with other unsecured resources. This is fixed in v0.52.16.4, v1.52.16.4, v0.53.8, and v1.53.8. Migrating to Metabase Cloud or redeploying Metabase in a dedicated subnet with strict outbound port controls is an available workaround. | ||||
| CVE-2024-7729 | 1 Cayintech | 15 Cms-20, Cms-60, Cms-se and 12 more | 2026-04-15 | 7.5 High |
| The CAYIN Technology CMS lacks proper access control, allowing unauthenticated remote attackers to download arbitrary CGI files. | ||||
| CVE-2024-7755 | 2026-04-15 | 8.2 High | ||
| The EWON FLEXY 202 transmits credentials using a weak encoding method base64. An attacker who is present in the network can sniff the traffic and decode the credentials. | ||||
| CVE-2024-8300 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Genesis64 | 2026-04-15 | 7 High |
| Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products. | ||||