Export limit exceeded: 10683 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (10683 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-22186 | 2026-04-15 | 8.8 High | ||
| The application suffers from a privilege escalation vulnerability. An attacker logged in as guest can escalate his privileges by poisoning the cookie to become administrator. | ||||
| CVE-2025-54719 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 8.8 High |
| Deserialization of Untrusted Data vulnerability in NooTheme Yogi - Health Beauty & Yoga noo-yogi allows Object Injection.This issue affects Yogi - Health Beauty & Yoga: from n/a through <= 2.9.2. | ||||
| CVE-2025-54723 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 9.8 Critical |
| Deserialization of Untrusted Data vulnerability in BoldThemes DentiCare denticare allows Object Injection.This issue affects DentiCare: from n/a through < 1.4.3. | ||||
| CVE-2025-54781 | 1 Himmelblau-idm | 1 Himmelblau | 2026-04-15 | 2.8 Low |
| Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. When debugging is enabled for Himmelblau in version 1.0.0, the himmelblaud_tasks service leaks an Intune service access token to the system journal. This short-lived token can be used to detect the host's Intune compliance status, and may permit additional administrative operations for the Intune host device (though the API for these operations is undocumented). This is fixed in version 1.1.0. To workaround this issue, ensure that Himmelblau debugging is disabled. | ||||
| CVE-2025-4742 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability classified as problematic has been found in XU-YIJIE grpo-flat up to 9024b43f091e2eb9bac65802b120c0b35f9ba856. Affected is the function main of the file grpo_vanilla.py. The manipulation leads to deserialization. Local access is required to approach this attack. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. | ||||
| CVE-2025-4740 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability was found in BeamCtrl Airiana up to 11.0. It has been declared as problematic. This vulnerability affects unknown code of the file coef. The manipulation leads to deserialization. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2024-47072 | 2 Redhat, X-stream | 4 Build Keycloak, Jboss Data Grid, Ocp Tools and 1 more | 2026-04-15 | 7.5 High |
| XStream is a simple library to serialize objects to XML and back again. This vulnerability may allow a remote attacker to terminate the application with a stack overflow error resulting in a denial of service only by manipulating the processed input stream when XStream is configured to use the BinaryStreamDriver. XStream 1.4.21 has been patched to detect the manipulation in the binary input stream causing the the stack overflow and raises an InputManipulationException instead. Users are advised to upgrade. Users unable to upgrade may catch the StackOverflowError in the client code calling XStream if XStream is configured to use the BinaryStreamDriver. | ||||
| CVE-2024-40624 | 1 Torrentpier | 1 Torrentpier | 2026-04-15 | 9.8 Critical |
| TorrentPier is an open source BitTorrent Public/Private tracker engine, written in php. In `torrentpier/library/includes/functions.php`, `get_tracks()` uses the unsafe native PHP serialization format to deserialize user-controlled cookies. One can use phpggc and the chain Guzzle/FW1 to write PHP code to an arbitrary file, and execute commands on the system. For instance, the cookie bb_t will be deserialized when browsing to viewforum.php. This issue has been addressed in commit `ed37e6e52` which is expected to be included in release version 2.4.4. Users are advised to upgrade as soon as the new release is available. There are no known workarounds for this vulnerability. | ||||
| CVE-2023-48010 | 2026-04-15 | 9.8 Critical | ||
| STMicroelectronics SPC58 is vulnerable to Missing Protection Mechanism for Alternate Hardware Interface. Code running as Supervisor on the SPC58 PowerPC microcontrollers may disable the System Memory Protection Unit and gain unabridged read/write access to protected assets. | ||||
| CVE-2025-46742 | 2026-04-15 | 4.3 Medium | ||
| Users who were required to change their password could still access system information before changing their password | ||||
| CVE-2025-46738 | 1 Schweitzer Engineering Laboratories | 1 Sel-5033 Acselerator Rtac Software | 2026-04-15 | 6.6 Medium |
| An authenticated attacker can maliciously modify layout data files in the SEL-5033 installation directory to execute arbitrary code. | ||||
| CVE-2023-32737 | 1 Siemens | 1 Simatic Step 7 | 2026-04-15 | 6.3 Medium |
| A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. | ||||
| CVE-2023-32736 | 1 Siemens | 9 Simatic S7-plcsim, Simatic Step 7, Simatic Wincc and 6 more | 2026-04-15 | 7.3 High |
| A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 SP5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 SP5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. | ||||
| CVE-2025-4393 | 2026-04-15 | 6.5 Medium | ||
| Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 | ||||
| CVE-2023-32735 | 1 Siemens | 11 Simatic Step 7, Simatic Step 7 Safety, Simatic Wincc and 8 more | 2026-04-15 | 6.5 Medium |
| A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. | ||||
| CVE-2023-30971 | 1 Palantir | 1 Gaia | 2026-04-15 | 6.8 Medium |
| Gotham Gaia application was found to be exposing multiple unauthenticated endpoints. | ||||
| CVE-2023-5937 | 2026-04-15 | 3.8 Low | ||
| On Windows systems, the Arc configuration files resulted to be world-readable. This can lead to information disclosure by local attackers, via exfiltration of sensitive data from configuration files. | ||||
| CVE-2025-55306 | 2026-04-15 | 9.8 Critical | ||
| GenX_FX is an advance IA trading platform that will focus on forex trading. A vulnerability was identified in the GenX FX backend where API keys and authentication tokens may be exposed if environment variables are misconfigured. Unauthorized users could gain access to cloud resources (Google Cloud, Firebase, GitHub, etc.). | ||||
| CVE-2023-7062 | 2026-04-15 | 8.8 High | ||
| The Advanced File Manager Shortcodes plugin for WordPress is vulnerable to Directory Traversal in all versions up to, and including, 2.4. This makes it possible for attackers with contributor access or higher to read the contents of arbitrary files on the server, which can contain sensitive information. | ||||
| CVE-2021-47706 | 1 Commax | 1 Biometric Access Control System | 2026-04-15 | N/A |
| COMMAX Biometric Access Control System 1.0.0 contains an authentication bypass vulnerability that allows unauthenticated attackers to access sensitive information and circumvent physical controls in smart homes and buildings by exploiting cookie poisoning. Attackers can forge cookies to bypass authentication and disclose sensitive information. | ||||