Export limit exceeded: 24264 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (24264 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-30479 | 1 Dell | 1 Cloudlink | 2026-11-03 | 8.4 High |
| Dell CloudLink, versions prior to 8.2, contain a vulnerability where a privileged user with known password can run command injection to gain control of system. | ||||
| CVE-2025-30299 | 2 Adobe, Microsoft | 2 Framemaker, Windows | 2026-11-03 | 7.8 High |
| Adobe Framemaker versions 2020.8, 2022.6 and earlier are affected by a Heap-based Buffer Overflow vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file. | ||||
| CVE-2025-29988 | 1 Dell | 522 14 Plus 2-in-1 Db04250, 14 Plus 2-in-1 Db04250 Firmware, 14 Plus Db14250 and 519 more | 2026-11-03 | 6.9 Medium |
| Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution. | ||||
| CVE-2025-21461 | 1 Qualcomm | 49 Fastconnect 6900, Fastconnect 6900 Firmware, Fastconnect 7800 and 46 more | 2026-11-03 | 7.8 High |
| Memory corruption when programming registers through virtual CDM. | ||||
| CVE-2025-20732 | 3 Mediatek, Mediatk, Openwrt | 18 Mt6890, Mt7615, Mt7622 and 15 more | 2026-11-03 | 4.2 Medium |
| In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege (when OceReducedNeighborReport is disabled). User interaction is not needed for exploitation. Patch ID: WCNCR00441510; Issue ID: MSV-4139. | ||||
| CVE-2025-20726 | 1 Mediatek | 90 Lr12a, Modem, Mt2735 and 87 more | 2026-11-03 | 7.5 High |
| In Modem, there is a possible out of bounds write due to an incorrect bounds check. This could lead to remote escalation of privilege, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01672598; Issue ID: MSV-4622. | ||||
| CVE-2025-20725 | 2 Mediatek, Mediatk | 141 Lr12a, Mt2735, Mt2737 and 138 more | 2026-11-03 | 7.5 High |
| In ims service, there is a possible out of bounds write due to a missing bounds check. This could lead to remote escalation of privilege, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01671924; Issue ID: MSV-4620. | ||||
| CVE-2025-20213 | 1 Cisco | 1 Catalyst Sd-wan Manager | 2026-11-03 | 5.5 Medium |
| A vulnerability in the CLI of Cisco Catalyst SD-WAN Manager, formerly Cisco SD-WAN vManage, could allow an authenticated, local attacker to overwrite arbitrary files on the local file system of an affected device. To exploit this vulnerability, the attacker must have valid read-only credentials with CLI access on the affected system. This vulnerability is due to improper access controls on files that are on the local file system. An attacker could exploit this vulnerability by running a series of crafted commands on the local file system of an affected device. A successful exploit could allow the attacker to overwrite arbitrary files on the affected device and gain privileges of the root user. To exploit this vulnerability, an attacker would need to have CLI access as a low-privilege user. | ||||
| CVE-2026-58879 | 1 Google | 1 Android | 2026-11-03 | 8.4 High |
| In descramble of multiple files, there is a possible out-of-bounds write due to improper casting. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. | ||||
| CVE-2026-120952 | 1 Mongodb | 1 Atlas Sql Odbc Driver | 2026-11-03 | 7.1 High |
| An out-of-bounds write in the MongoDB Atlas SQL ODBC Driver may be triggered when a value of a particular database type is retrieved into a fixed-width client-side target. The driver produces a textual form of the value that is longer than the fixed target the ODBC interface defines, and copies it without limiting the copy to the target's real size. A database user with basic write privileges can influence part of the data written outside the target, which may corrupt memory in the application using the driver and cause that application to terminate unexpectedly. | ||||
| CVE-2026-113029 | 1 Google | 1 Chrome | 2026-11-03 | 8.8 High |
| Out of bounds write in ANGLE in Google Chrome prior to 156.0.8078.47 allowed a remote attacker who had compromised the renderer process to potentially execute arbitrary code outside the sandbox via a crafted HTML page. (Chromium security severity: Low) | ||||
| CVE-2026-113293 | 2 Google, Microsoft | 2 Chrome, Windows | 2026-11-03 | 8.8 High |
| Out of bounds write in ANGLE in Google Chrome on on Windows prior to 156.0.8078.47 allowed a remote attacker to execute arbitrary code outside the sandbox via a crafted HTML page. (Chromium security severity: High) | ||||
| CVE-2026-118335 | 2 Apple, Google | 2 Macos, Chrome | 2026-11-03 | 8.8 High |
| Out of bounds write in Metrics in Google Chrome on on Mac prior to 156.0.8078.73 allowed a remote attacker who had compromised the renderer process to potentially execute arbitrary code outside the sandbox via a crafted file. (Chromium security severity: High) | ||||
| CVE-2026-118342 | 1 Google | 1 Chrome | 2026-11-03 | 9.6 Critical |
| Use after free in Editing in Google Chrome prior to 156.0.8078.73 allowed a remote attacker to execute arbitrary code inside the sandbox via a crafted HTML page. (Chromium security severity: High) | ||||
| CVE-2026-118313 | 1 Google | 1 Chrome | 2026-11-03 | 8.8 High |
| Out of bounds write in Video in Google Chrome prior to 156.0.8078.73 allowed a remote attacker to execute arbitrary code inside the sandbox via a crafted HTML page. (Chromium security severity: High) | ||||
| CVE-2026-119262 | 1 Google | 1 Chrome | 2026-11-03 | 8.8 High |
| Out of bounds write in V8 in Google Chrome prior to 156.0.8078.79 allowed a remote attacker to execute arbitrary code inside the sandbox via a crafted HTML page. (Chromium security severity: High) | ||||
| CVE-2026-84627 | 1 Apple | 5 Ios And Ipados, Ipados, Iphone Os and 2 more | 2026-11-03 | 7.8 High |
| A buffer overflow was addressed with improved bounds checking. This issue is fixed in iOS 26.7.2 and iPadOS 26.7.2, iOS 27 and iPadOS 27, macOS Golden Gate 27, macOS Sequoia 15.8, macOS Tahoe 26.7.2, visionOS 27. Processing a maliciously crafted image may lead to heap corruption. | ||||
| CVE-2026-112691 | 1 Apple | 5 Ios And Ipados, Ipados, Iphone Os and 2 more | 2026-11-03 | 6.2 Medium |
| An out-of-bounds write issue was addressed with improved input validation. This issue is fixed in iOS 26.7.2 and iPadOS 26.7.2, iOS 27.2 and iPadOS 27.2, visionOS 27.2, watchOS 27.2. An app may be able to cause unexpected system termination. | ||||
| CVE-2026-120959 | 2026-11-03 | 3.7 Low | ||
| A memory-handling flaw in the MongoDB Atlas SQL ODBC Driver can cause values returned for a query to be written outside the bounds of a buffer provided by the calling application. A party able to influence the values a query returns may cause data to be placed at an unintended location in the client application's memory, which may result in unintended modification of that memory or termination of the client process. Reaching this condition depends on a specific, application-chosen way of requesting several result rows at once. | ||||
| CVE-2026-8913 | 1 Tp-link | 1 Archer Mr600 | 2026-11-03 | N/A |
| A command Injection vulnerability exists in the WireGuard client configuration of Archer MR600 v2, v3, and v5 due to improper neutralization of user-controlled input within the web management interface. An authenticated attacker with administrative privileges may be able to execute arbitrary commands when applying configuration changes.Successful exploitation may result in a full compromise of confidentiality, integrity, and availability of the affected device. | ||||