| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| OS Command Injection in iSTAR Ultra products web application allows an authenticated attacker to gain even more privileged access ('root' user) to the device firmware. |
| OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340 provided by Y'S corporation. An attacker who can access the affected product may execute an arbitrary OS command. |
| GitHub Kanban MCP Server is a Model Context Protocol (MCP) server for managing GitHub issues in Kanban board format and streamlining LLM task management. Version 0.3.0 of the MCP Server is written in a way that is vulnerable to command injection vulnerability attacks as part of some of its MCP Server tool definition and implementation. The MCP Server exposes the tool `add_comment` which relies on Node.js child process API `exec` to execute the GitHub (`gh`) command, is an unsafe and vulnerable API if concatenated with untrusted user input. As of time of publication, no known patches are available. |
| OpenOps before 0.6.11 allows remote code execution in the Terraform block. |
| A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer. |
| squid/cachemgr.cgi in Webmin before 2.600 does not properly quote arguments. This is relevant if Webmin's Squid module and its Cache Manager feature are available, and an untrusted party is able to authenticate to Webmin and has certain Cache Manager permissions (the "cms" security option). |
| Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') |
| Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') |
| EnGenius ENH1350EXT A8J-ENH1350EXT devices through 3.9.3.2_c1.9.51 allow (blind) OS Command Injection via shell metacharacters to the Ping or Speed Test utility. During the time of initial setup, the device creates an open unsecured network whose admin panel is configured with the default credentials of admin/admin. An unauthorized attacker in proximity to the Wi-Fi network can exploit this window of time to execute arbitrary OS commands with root-level permissions. |
| TOTOLINK N300RT wireless router firmware versions prior to V3.4.0-B20250430 (discovered in V2.1.8-B20201030.1539) contain an OS command injection vulnerability in the Boa formWsc handling functionality. An unauthenticated attacker can send specially crafted requests to trigger command execution via the targetAPSsid request parameter. |
| Certain hybrid DVR models (HBF-09KD and HBF-16NK) from Hunt Electronic have an OS Command Injection vulnerability, allowing remote attackers with regular privileges to inject arbitrary OS commands and execute them on the device. |
| Multiple wireless router models from Sapido have an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. The affected models are out of support; replacing the device is recommended. |
| An issue was discovered in Pacom Unison Client 5.13.1. Authenticated users can inject malicious scripts in the Report Templates which are executed when certain script conditions are fulfilled, leading to Remote Code Execution. |
| mcp-remote is exposed to OS command injection when connecting to untrusted MCP servers due to crafted input from the authorization_endpoint response URL |
| This CVE affects only Windows worker nodes. Your worker node is vulnerable to this issue if it is running one of the affected versions listed below. |
| cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of validation in the langGet parameter in the adm.cgi endpoint, the malicious attacker can execute system shell commands.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Fujitsu fbiosdrv.sys before 2.5.0.0 allows an attacker to potentially affect system confidentiality, integrity, and availability. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |