Search Results (24332 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-61600 1 Stalwartlabs 1 Stalwart 2026-04-15 7.5 High
Stalwart is a mail and collaboration server. Versions 0.13.3 and below contain an unbounded memory allocation vulnerability in the IMAP protocol parser which allows remote attackers to exhaust server memory, potentially triggering the system's out-of-memory (OOM) killer and causing a denial of service. The CommandParser implementation enforces size limits on its dynamic buffer in most parsing states, but several state handlers omit these validation checks. This issue is fixed in version 0.13.4. A workaround for this issue is to implement rate limiting and connection monitoring at the network level, however this does not provide complete protection.
CVE-2025-6181 2 Microsoft, Strongdm 2 Windows, Sdm-cli 2026-04-15 N/A
The StrongDM Windows service incorrectly handled input validation. Authenticated attackers could potentially exploit this leading to privilege escalation.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-6183 2 Apple, Strongdm 2 Macos, Sdm-cli 2026-04-15 N/A
The StrongDM macOS client incorrectly processed JSON-formatted messages. Attackers could potentially modify macOS system configuration by crafting a malicious JSON message.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-42503 1 Arubanetworks 1 Arubaos 2026-04-15 7.2 High
Authenticated command execution vulnerability exist in the ArubaOS command line interface (CLI). Successful exploitation of this vulnerabilities result in the ability to run arbitrary commands as a priviledge user on the underlying operating system.
CVE-2024-42502 1 Arubanetworks 1 Arubaos 2026-04-15 7.2 High
Authenticated command injection vulnerability exists in the ArubaOS command line interface. Successful exploitation of this vulnerability result in the ability to inject shell commands on the underlying operating system.
CVE-2025-61910 1 Nasajpl 1 Iondtn 2026-04-15 7.5 High
The NASA’s Interplanetary Overlay Network (ION) is an implementation of Delay/Disruption Tolerant Networking (DTN). A BPv7 bundle with a malformed extension block causes uncontrolled memory allocation inside ION-DTN 4.1.3s, leading to receiver thread termination and a Denial-of-Service (DoS). The triggering bundle contains an extension block starting at `0x85070201005bbb0e20b4ea001a000927c0...`. The first byte in the extension block (0x85) indicates a CBOR array of five elements of which the first four are numbers (0x07, 0x02, 0x01, 0x00) but the fifth element is a byte string of length 27 (`0x5bbb0e20b4ea001a000927c0...`). The vulnerability seems to be due to processing the fifth element of the array (i.e., the byte string) as replacing it with a number makes the vulnerability no longer be triggered. While parsing this extension block, ION obtains a very large block length, which in the code in `bei.c`:764) seems to be passed from `blockLength` which is an unsigned int, to a 32 bit signed integer `blkSize`. The unsigned to signed conversion causes `blkSize` to hold the value of -369092043, which is then converted into a 64-bit unsigned value inside `MTAKE(blkSize)`, resulting in an attempt to allocate an unrealistic amount of memory, causing the error. As of time of publication, no known patched versions of BPv7 exist.
CVE-2025-6193 1 Redhat 1 Openshift Ai 2026-04-15 5.9 Medium
A command injection vulnerability was discovered in the TrustyAI Explainability toolkit. Arbitrary commands placed in certain fields of a LMEValJob custom resource (CR) may be executed in the LMEvalJob pod's terminal. This issue can be exploited via a maliciously crafted LMEvalJob by a user with permissions to deploy a CR.
CVE-2025-62193 1 Noaa 1 Live Access Server 2026-04-15 9.8 Critical
Sites running NOAA PMEL Live Access Server (LAS) are vulnerable to remote code execution via specially crafted requests that include PyFerret expressions. By leveraging a SPAWN command, a remote, unauthenticated attacker can execute arbitrary OS commands. Fixed in a version of 'gov.noaa.pmel.tmap.las.filter.RequestInputFilter.java' from 2025-09-24.
CVE-2025-6225 2026-04-15 N/A
Kieback&Peter Neutrino-GLT product is used for building management. It's web component "SM70 PHWEB" is vulnerable to shell command injection via login form. The injected commands would execute with low privileges. The vulnerability has been fixed in version 9.40.02
CVE-2024-42370 1 Litestar-org 1 Litestar 2026-04-15 8.3 High
Litestar is an Asynchronous Server Gateway Interface (ASGI) framework. In versions 2.10.0 and prior, Litestar's `docs-preview.yml` workflow is vulnerable to Environment Variable injection which may lead to secret exfiltration and repository manipulation. This issue grants a malicious actor the permission to write issues, read metadata, and write pull requests. In addition, the `DOCS_PREVIEW_DEPLOY_TOKEN` is exposed to the attacker. Commit 84d351e96aaa2a1338006d6e7221eded161f517b contains a fix for this issue.