Search Results (17082 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-32072 2026-04-15 N/A
Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki Core - Feed Utils allows WebView Injection.This issue affects Mediawiki Core - Feed Utils: from 1.39 through 1.43.
CVE-2024-28815 1 Mitel 2 Cmg Suite, Inattend 2026-04-15 9.8 Critical
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
CVE-2024-36434 1 Supermicro 3 X11dph-i, X11dph-t, X11dph-tq 2026-04-15 7.5 High
An SMM callout vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4.
CVE-2024-36433 1 Supermicro 3 X11dph-i, X11dph-t, X11dph-tq 2026-04-15 7.5 High
An arbitrary memory write vulnerability was discovered in Supermicro X11DPH-T, X11DPH-Tq, and X11DPH-i motherboards with BIOS firmware before 4.4.
CVE-2024-29022 2026-04-15 8.8 High
Xibo is an Open Source Digital Signage platform with a web content management system and Windows display player software. In affected versions some request headers are not correctly sanitised when stored in the session and display tables. These headers can be used to inject a malicious script into the session page to exfiltrate session IDs and User Agents. These session IDs / User Agents can subsequently be used to hijack active sessions. A malicious script can be injected into the display grid to exfiltrate information related to displays. Users should upgrade to version 3.3.10 or 4.0.9 which fix this issue. Customers who host their CMS with the Xibo Signage service have already received an upgrade or patch to resolve this issue regardless of the CMS version that they are running. Upgrading to a fixed version is necessary to remediate. Patches are available for earlier versions of Xibo CMS that are out of security support: 2.3 patch ebeccd000b51f00b9a25f56a2f252d6812ebf850.diff. 1.8 patch a81044e6ccdd92cc967e34c125bd8162432e51bc.diff. There are no known workarounds for this issue.
CVE-2024-36319 1 Amd 14 Instinct Mi300a, Instinct Mi300x, Instinct Mi308x and 11 more 2026-04-15 N/A
Debug code left active in AMD's Video Decoder Engine Firmware (VCN FW) could allow a attacker to submit a maliciously crafted command causing the VCN FW to perform read/writes HW registers, potentially impacting confidentiality, integrity and availabilability of the system.
CVE-2024-36292 2026-04-15 7.3 High
Improper buffer restrictions for some Intel(R) Data Center GPU Flex Series for Windows driver before version 31.0.101.4314 may allow an authenticated user to potentially enable denial of service via local access.
CVE-2025-2851 2026-04-15 8 High
A vulnerability classified as critical has been found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. Affected is an unknown function of the file plugins.so of the component RPC Handler. The manipulation leads to buffer overflow. It is recommended to upgrade the affected component.
CVE-2024-30253 2026-04-15 7.5 High
@solana/web3.js is the Solana JavaScript SDK. Using particular inputs with `@solana/web3.js` will result in memory exhaustion (OOM). If you have a server, client, mobile, or desktop product that accepts untrusted input for use with `@solana/web3.js`, your application/service may crash, resulting in a loss of availability. This vulnerability is fixed in 1.0.1, 1.10.2, 1.11.1, 1.12.1, 1.1.2, 1.13.1, 1.14.1, 1.15.1, 1.16.2, 1.17.1, 1.18.1, 1.19.1, 1.20.3, 1.21.1, 1.22.1, 1.23.1, 1.24.3, 1.25.1, 1.26.1, 1.27.1, 1.28.1, 1.2.8, 1.29.4, 1.30.3, 1.31.1, 1.3.1, 1.32.3, 1.33.1, 1.34.1, 1.35.2, 1.36.1, 1.37.3, 1.38.1, 1.39.2, 1.40.2, 1.41.11, 1.4.1, 1.42.1, 1.43.7, 1.44.4, 1.45.1, 1.46.1, 1.47.5, 1.48.1, 1.49.1, 1.50.2, 1.51.1, 1.5.1, 1.52.1, 1.53.1, 1.54.2, 1.55.1, 1.56.3, 1.57.1, 1.58.1, 1.59.2, 1.60.1, 1.61.2, 1.6.1, 1.62.2, 1.63.2, 1.64.1, 1.65.1, 1.66.6, 1.67.3, 1.68.2, 1.69.1, 1.70.4, 1.71.1, 1.72.1, 1.7.2, 1.73.5, 1.74.1, 1.75.1, 1.76.1, 1.77.4, 1.78.8, 1.79.1, 1.80.1, 1.81.1, 1.8.1, 1.82.1, 1.83.1, 1.84.1, 1.85.1, 1.86.1, 1.87.7, 1.88.1, 1.89.2, 1.90.2, 1.9.2, and 1.91.3.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-26503 1 Windriver 1 Vxworks 2026-04-15 6.7 Medium
A crafted system call argument can cause memory corruption.
CVE-2025-26409 2026-04-15 6.8 Medium
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1.
CVE-2025-26408 2026-04-15 6.1 Medium
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected.
CVE-2025-2521 2026-04-15 8.6 High
The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS: 520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
CVE-2022-38692 2026-04-15 9.8 Critical
In BootROM, there is a missing size check for RSA keys in Certificate Type 0 validation. This could lead to memory buffer overflow without requiring additional execution privileges.
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2025-24338 2026-04-15 7.1 High
A vulnerability in the “Manages app data” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to execute arbitrary client-side code in the context of another user's browser via multiple crafted HTTP requests.
CVE-2022-38693 2026-04-15 9.8 Critical
In FDL1, there is a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges.
CVE-2022-38696 2026-04-15 9.8 Critical
In BootRom, there's a possible missing payload size check. This could lead to memory buffer overflow without requiring additional execution privileges.