| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. |
| Aodh as packaged in Openstack Ocata and Newton before change-ID I8fd11a7f9fe3c0ea5f9843a89686ac06713b7851 and before Pike-rc1 does not verify that trust IDs belong to the user when creating alarm action with the scheme trust+http, which allows remote authenticated users with knowledge of trust IDs where Aodh is the trustee to obtain a Keystone token and perform unspecified authenticated actions by adding an alarm action with the scheme trust+http, and providing a trust id where Aodh is the trustee. |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |
| A potential security vulnerability has been identified in HPE Application Performance Management (BSM) Platform versions 9.26, 9.30, 9.40. The vulnerability could be remotely exploited to allow code execution. |
| register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services. |
| IBM Security Identity Manager Adapters 6.0 and 7.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 128621. |
| Weak access control methods on the TP-Link TL-SG108E 1.0.0 allow any user on a NAT network with an authenticated administrator to access the device without entering user credentials. The authentication record is stored on the device; thus if an administrator authenticates from a NAT network, the authentication applies to the IP address of the NAT gateway, and any user behind that NAT gateway is also treated as authenticated. |
| Weak access controls in the Device Logout functionality on the TP-Link TL-SG108E v1.0.0 allow remote attackers to call the logout functionality, triggering a denial of service condition. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request. |
| Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter. |
| Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication. |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. |
| A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. |
| A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392. |