| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information. |
| A potential missing authentication vulnerability was reported in some Lenovo Tablets that could allow an unauthorized user with physical access to modify Control Center settings if the device is locked when the "Allow Control Center access when locked" option is disabled. |
| An issue in Quectel BG96 BG96MAR02A08M1G allows attackers to bypass authentication via a crafted NAS message. NOTE: this is disputed by the supplier. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| PutongOJ is online judging software. Prior to version 2.1.0-beta.1, unprivileged users can escalate privileges by constructing requests. This can lead to unauthorized access, enabling users to perform admin-level operations, potentially compromising sensitive data and system integrity. This problem has been fixed in v2.1.0.beta.1. As a workaround, one may apply the patch from commit `211dfe9` manually. |
| CVE-2025-1701 is a high-severity vulnerability in the MIM Admin service. An attacker could exploit this vulnerability by sending a specially crafted request over the RMI interface to execute arbitrary code with the privileges of the MIM Admin service. The RMI interface is only accessible locally (listening on 127.0.0.1), limiting the attack vector to the local machine. This means that in a properly configured hospital environment, an attacker must have already compromised the network and additionally compromised the system where the MIM Admin service is running. From there, attackers with sufficient knowledge of MIM's implementation, library usage, and functionality with access to extend the MIM RMI library could force the MIM Admin service to run commands on the local machine with its privileges.
Users of MIM Software products exposed via RDP or multi-user application virtualization system should take note that the system being exposed is the environment hosting the virtualized MIM client.
This issue affects MIM Admin Service: before 7.2.13, 7.3.8, 7.4.3 |
| An issue in Plug n Play Camera com.starvedia.mCamView.zwave 5.5.1 allows a remote attacker to obtain sensitive information via the firmware update process |
| LEDVANCE com.ledvance.smartplus.eu 2.1.10 allows a remote attacker to obtain sensitive information via the firmware update process. |
| NVIDIA Delegated Licensing Service for all appliance platforms contains a vulnerability where an User/Attacker may cause an authorized action. A successful exploit of this vulnerability may lead to information disclosure. |
| Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) versions prior to 1.3.4 contain an authentication bypass in the NVMS-9000 control protocol. By sending a single crafted TCP payload to an exposed NVMS-9000 control port, an unauthenticated remote attacker can invoke privileged administrative query commands without valid credentials. Successful exploitation discloses sensitive information including administrator usernames and passwords in cleartext, network and service configuration, and other device details via commands such as queryBasicCfg, queryUserList, queryEmailCfg, queryPPPoECfg, and queryFTPCfg. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| A file handling command vulnerability in certain versions of Armoury Crate may result in arbitrary file deletion.
Refer to the '01/23/2025 Security Update for Armoury Crate App' section on the ASUS Security Advisory for more information. |
| WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could
allow an attacker to create an administrator account without knowing any
existing credentials. |
| The CE Phoenix eCommerce platform, starting in version 1.0.9.7 and prior to version 1.1.0.3, allowed logged-in users to delete their accounts without requiring password re-authentication. An attacker with temporary access to an authenticated session (e.g., on a shared/public machine) could permanently delete the user’s account without knowledge of the password. This bypass of re-authentication puts users at risk of account loss and data disruption. Version 1.1.0.3 contains a patch for the issue. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| Authentication Bypass
vulnerability in Hitachi Ops Center Analyzer on Linux, 64 bit (Hitachi Ops Center Analyzer detail view component), Hitachi Infrastructure Analytics Advisor on Linux, 64 bit (Hitachi Data Center Analytics
component
).This issue affects Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.3-00; Hitachi Infrastructure Analytics Advisor: from 2.1.0-00 through 4.4.0-00. |
| An issue was discovered in Cicool builder 3.4.4 allowing attackers to reset the administrator's password via the /administrator/auth/reset_password endpoint. |